IN-LINE MONITORED UNIT WITH FRENCH TYPE SOCKETS -
1U
|
Two In-Line monitored
circuits max. 16A/230VAC each.
2 (1 +1) UTE sockets outlet (French standard) max. 16A/230VAC.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 431x44x44mm.
Vertical or horizontal mounting in 19” rack - 1U.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.3G1,5mm² in white and black colour with
standard length up to 10m.
Cables terminated
unischuko angled plugs
16A/230V.
Maximum current 2 x 16A (2 x 3 680 W).
Mains voltage 230 VAC
Two AC ammeters with 3 digits LED display.
- Measurement range 0,1...16A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
2
|
unischuko
|
UTE
|
MXLL07B20A
|
MXLL07B201
|
MXLL07B202
|
MXLL07B203
|
|
IN-LINE MONITORED UNIT WITH IEC320C19 TYPE SOCKETS
-
1U
|
Two In-Line monitored
circuits max. 16A/230VAC each.
2 (1+1) IEC320C19 sockets outlet max. 16A/230VAC.
Plastic elements colour: light-grey similar to RAL7035 or black
similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 431x44x46mm.
Vertical or horizontal mounting in 19” rack - 1U.
Mounting brackets for installation in 4 orientations.
Two supply sockets IEC320C20 16A/230VAC (strip supplied without power
cords).
Maximum current 2 x 16A (2 x 3 680 W).
Mains voltage 230 VAC
Two AC ammeters with 3 digits LED display.
- Measurement range 0,1...16A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
catalogue
number
|
2
|
IEC320C20
|
IEC320C19
|
MXLL0DH2XX
|
|
IN-LINE MONITORED UNIT WITH IEC60309 16A/230V INLET
/ OUTLET
|
One In-Line monitored
circuit max. 16A/230VAC.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 44x302x44mm.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.3G1,5mm² in white or black colour with
standard length up to 10m.
Inlet cable terminated
IEC60309 plug
16A/230V.
Outlet cable terminated IEC60309 socket 16A/230V.
Maximum current 16A (3 680 W).
Mains voltage 230 VAC
AC ammeter with 3 digits LED display.
- Measurement range 0,1...16A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
1
|
IEC60309
|
IEC60309
|
MXLL01Y1AA
|
MXLL01Y111
|
MXLL01Y122
|
MXLL01Y133
|
|
IN-LINE MONITORED UNIT WITH IEC60309 16A/230V
INLETS
/ OUTLETS - 1U
|
Two In-Line monitored
circuits max. 16A/230VAC each.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 431x44x44mm.
Vertical or horizontal mounting in 19” rack - 1U.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.3G1,5mm² in white or black colour with
standard length up to 10m.
Inlet cables terminated
IEC60309 plugs
16A/230V.
Outlet cables terminated IEC60309 sockets 16A/230V.
Maximum current 2 x 16A (2 x 3 680 W).
Mains voltage 230 VAC
Two AC ammeters with 3 digits LED display.
- Measurement range 0,1...16A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
2
|
IEC60309
|
IEC60309
|
MXLL01Y2AA
|
MXLL01Y211
|
MXLL01Y222
|
MXLL01Y233
|
|
IN-LINE MONITORED UNIT WITH IEC60309 32A/230V INLET
/ OUTLET
|
One In-Line monitored
circuit max. 32A/230VAC.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 44x302x44mm.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.3G4mm² in white or black colour with
standard length up to 10m.
Inlet cable terminated
IEC60309 plug 32A/230V.
Outlet cable terminated IEC60309 socket 32A/230V.
Maximum current 32A (7 360 W).
Mains voltage 230 VAC
AC ammeter with 3 digits LED display.
- Measurement range 0,1...32A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
1
|
IEC60309
|
IEC60309
|
MXLL11W1AA
|
MXLL11W111
|
MXLL11W122
|
MXLL11W133
|
|
IN-LINE MONITORED UNIT WITH IEC60309 32A/230V
INLETS
/ OUTLETS - 1U
|
Two In-Line monitored
circuits max. 32A/230VAC each.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 431x44x44mm.
Vertical or horizontal mounting in 19” rack - 1U.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.3G4mm² in white or black colour with
standard length up to 10m.
Inlet cables terminated
IEC60309 plugs 32A/230V.
Outlet cables terminated IEC60309 sockets 32A/230V.
Maximum current 2 x 32A (2 x 7 360 W).
Mains voltage 230 VAC
Two AC ammeters with 3 digits LED display.
- Measurement range 0,1...32A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
2
|
IEC60309
|
IEC60309
|
MXLL11W2AA
|
MXLL11W211
|
MXLL11W222
|
MXLL11W233
|
|
IN-LINE MONITORED UNIT WITH IEC60309 INLET
/ OUTLET - 3 PHASE 48A (3
x 16A)
|
One In-Line monitored
circuit max. 3 x 16A/230VAC.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 431x44x44mm.
Vertical or horizontal mounting in 19” rack - 1U.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.5G2,5mm² in white or black colour with
standard length up to 10m.
Inlet cable terminated
IEC60309 plug 3x16A/400V.
Outlet cable terminated IEC60309 socket 3x16A/400V.
Maximum current 48A (11 040 W).
Mains voltage 230 VAC
Three AC ammeters with 3 digits LED display.
- Measurement range 0,1...16A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
1
|
IEC60309
|
IEC60309
|
MXLL21Z1AA
|
MXLL21Z111
|
MXLL21Z122
|
MXLL21Z133
|
|
IN-LINE MONITORED UNIT WITH IEC60309 INLET
/ OUTLET - 3 PHASE 96A (3
x 32A)
|
One In-Line monitored
circuit max. 3 x 32A/230VAC.
Plastic elements colour: light-grey similar to RAL7035 or black similar
to RAL9005.
Natural anodized aluminium body.
Dimension without mounting brackets WxHxD: 431x44x44mm.
Vertical or horizontal mounting in 19” rack - 1U.
Mounting brackets for installation in 4 orientations.
Supply cables H05VVF.5G4mm² in white or black colour with
standard length up to 10m.
Inlet cable terminated
IEC60309 plug 3x32A/400V.
Outlet cable terminated IEC60309 socket 3x32A/400V.
Maximum current 96A (22 080 W).
Mains voltage 230 VAC
Three AC ammeters with 3 digits LED display.
- Measurement range 0,1...32A.
- Measurement accurate ±2,5%.
Build-in web-server with monitoring of supply circuits,
current load and temperature.
- Network interface: Ethernet RJ45
(Ethernet 10/100BaseT).
- RJ11 interface for optional
temperature sensor
- Protocols: TCP/IP, HTTP, SNMP, SMTP,
Syslog, DHCP.
Protection level IP20.
Declaration of Conformity CE.
Number of
circuits
|
supply
plugs
|
outlets
|
power
supply cable length
|
0,5 m
|
1 m
|
2 m
|
3 m
|
1
|
IEC60309
|
IEC60309
|
MXLL31T1AA
|
MXLL31T111
|
MXLL31T122
|
MXLL31T133
|
|
|
|
|